Item |
DT |
Card |
Conf |
Desc |
Label |
|
|
1..1 |
M |
|
(infuus) |
|
@classCode
|
|
|
1..1 |
F |
SPLY |
|
@moodCode
|
|
|
1..1 |
F |
EVN |
|
Voorbeeld |
<supply classCode="SPLY" moodCode="EVN">
<templateId root="2.16.840.1.113883.2.4.6.10.30.2.119"/>
<code code="19923001" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Catheter"/>
<statusCode code="completed"/>
<effectiveTime value="20111108"/>
<product>
<!-- ... -->
</product>
<entryRelationship typeCode="REFR">
<!-- ... -->
</entryRelationship>
<entryRelationship typeCode="SUBJ">
<!-- ... -->
</entryRelationship> </supply> |
|
hl7:templateId
|
|
II |
1..1 |
M |
Bevat informatie over de feitelijk in gebruik zijnde infuus |
(infuus) |
|
|
@root
|
|
|
1..1 |
F |
2.16.840.1.113883.2.4.6.10.30.2.119 |
|
Voorbeeld |
<templateId root="2.16.840.1.113883.2.4.6.10.30.2.119"/>
|
|
hl7:code
|
|
CE |
1..1 |
M |
|
(infuus) |
|
|
@code
|
|
|
1..1 |
F |
19923001 |
|
|
@codeSystem
|
|
|
1..1 |
F |
2.16.840.1.113883.6.96 (SNOMED CT) |
|
Voorbeeld |
<code code="19923001" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Catheter"/>
|
|
hl7:statusCode
|
|
CS |
0..1 |
O |
|
(infuus) |
|
|
@code
|
|
|
1..1 |
F |
completed |
|
Voorbeeld |
<statusCode code="completed"/>
|
|
hl7:effectiveTime
|
|
TS |
0..1 |
O |
Datum plaatsing infuus. Afhanelijk van soort infuus |
(infuus) |
|
Voorbeeld |
<effectiveTime value="20111108"/>
|
|
hl7:product
|
|
|
1..1 |
M |
|
(infuus) |
|
Voorbeeld |
<product>
<manufacturedProduct classCode="MANU">
<!-- ... -->
</manufacturedProduct> </product> |
|
|
hl7:manufacturedProduct
|
|
|
1..1 |
M |
|
(infuus) |
|
|
1..1 |
F |
MANU |
|
Voorbeeld |
<manufacturedProduct classCode="MANU">
<manufacturedMaterial classCode="MMAT">
<!-- ... -->
</manufacturedMaterial> </manufacturedProduct> |
|
|
1..1 |
M |
|
(infuus) |
|
|
1..1 |
F |
MMAT |
|
Voorbeeld |
<manufacturedMaterial classCode="MMAT">
<code code="52124006" codeSystem="2.16.840.1.113883.6.96" displayName="centrale veneuze katheter"/>
</manufacturedMaterial> |
|
CE |
1..1 |
M |
|
(infuus) |
|
|
1..1 |
F |
52124006 |
|
|
1..1 |
F |
2.16.840.1.113883.6.96 (SNOMED CT) |
|
Voorbeeld |
<code code="52124006" codeSystem="2.16.840.1.113883.6.96" displayName="centrale veneuze katheter"/>
|
|
hl7:entryRelationship waar [hl7:observation [hl7:templateId [@root='2.16.840.1.113883.2.4.6.10.30.2.121']]] |
|
|
0..1 |
O |
Element is aanwezig afhankelijk van infuus |
(infuus) |
|
|
@typeCode
|
|
|
1..1 |
F |
REFR |
|
Voorbeeld |
<entryRelationship typeCode="REFR">
<observation classCode="OBS" moodCode="EVN">
<!-- ... -->
</observation> </entryRelationship> |
|
Bevat |
geërfde templateregels infuus_locatie met overschreven kardinaliteit 0 .. 1 conditioneel
|
|
hl7:entryRelationship waar [hl7:substanceAdministration [hl7:templateId [@root='2.16.840.1.113883.2.4.6.10.30.2.122']]] |
|
|
0..1 |
O |
Element is aanwezig afhankelijk van infuus |
(infuus) |
|
|
@typeCode
|
|
|
1..1 |
F |
SUBJ |
|
Voorbeeld |
<entryRelationship typeCode="SUBJ">
<substanceAdministration moodCode="EVN" classCode="SBADM">
<!-- ... -->
</substanceAdministration> </entryRelationship> |
|
Bevat |
geërfde templateregels vloeistof_toe_te_dienen_via_infuus met overschreven kardinaliteit 0 .. 1 conditioneel
|